English term
bonded neutral
English to French
Tech/Engineering
Electronics / Elect Eng
If you are connecting your generator to a panel board transfer switch, a licensed electrician will need to consider removing the bonded neutral to ensure proper operation of household GFCI circuits.
Proposed translations
(French)
3 +1 | neutre relié | Alain Boulé |
4 +3 | neutre connecté à la terre | FX Fraipont (X) |
Proposed translations
+1
17 mins
Selected
neutre relié
Suggestion
4 KudoZ points awarded for this answer.
Comment: "Merci Alain.
For the technically inclined:
http://ezgeneratorswitch.com/need-know-generator-type-bonded-floating-neutral/"
+3
3 hrs
neutre connecté à la terre
"According to the North American electrical code (US and Canada), Neutral and Safety Ground must be bonded at the service entrance (or main breaker panel). The green wilre will also be connected to Earth via a ground rod driven into the earth near the service entrance. Neutral will also be grounded at the power pole and distribution transformer.
All this grounding ensures that the AC wiring is kept near earth potential, and won't drift up to 12 KV due to a fault in the distribution transformer."
https://electronics.stackexchange.com/questions/120940/why-a...
"XL PRO³ calcul | Legrand
http://www.legrand.be/fr/xlprocalcul/info
TT (neutre et masses connectés séparément à la terre); TN (neutre connecté à la terre, masses connectées au neutre, conducteurs N et PE séparés ou ..."
All this grounding ensures that the AC wiring is kept near earth potential, and won't drift up to 12 KV due to a fault in the distribution transformer."
https://electronics.stackexchange.com/questions/120940/why-a...
"XL PRO³ calcul | Legrand
http://www.legrand.be/fr/xlprocalcul/info
TT (neutre et masses connectés séparément à la terre); TN (neutre connecté à la terre, masses connectées au neutre, conducteurs N et PE séparés ou ..."
Peer comment(s):
agree |
Tony M
: Yes, it has to be understood as 'earth-bonded neutral'; perhaps 'relié', in line with common technical usage?
5 hrs
|
agree |
Daryo
14 hrs
|
agree |
Eric KUATE FOTSO
15 hrs
|
neutral |
Johannes Gleim
: No RCD will trigger in case of leakage fault if an earthed neutral or PE is connected to the device. The neutral has to be unearthed! The PEN must be split into PE (bonded to the enclosure) and N upstream of the RCD.
1 day 2 hrs
|